Rms-technologies R208 DRIVER Manual de usuario Pagina 11

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 16
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 10
RMS Technologies Page 11 Version 1.22
R208 Microstepping Driver Manual 8/31/2007
Alternative Step Resolution Connection
It is possible to change the microstepping resolution by using the signal from the
controller.
Figure 5: Alternative Step Resolution Connection
By sending a high signal to Pin 2 and/or Pin 3, the connection between these pins
will be effectively closed with Pin 7. This will change the microstepping resolution.
Please refer to the Table 3 for Step Resolution Settings.
NOTE: The microstepping resolution should not be changed on the fly, loss of step
may occur.