RMS Technologies Page 32 Version 1.31
R101 Single Axis Driver/Indexer Manual 10/1/2007
SD
S
ave Data
Command Only
This command causes a set of parameter values to be written to non-volatile
memory. On power up the last set of values written are set to be the parameter
initial values.
The parameters whose values are thus saved are:
My Address
Absolute Position
Velocity Limit
Minimum Velocity
Start Velocity
Acceleration
Hold Timeout
Step Resolution
Run Current
Hold Current
Percent Fast Decay
Command Example
#ASD<cr><lf> Saves Data.